A
The use of the Aged Sample Identifier (a software feature that needs to be activated) on XN-Class analysers allows a reliable differentiation of samples with abnormal WDF scattergrams into truly pathologic samples or aged samples. This application effectively prevents false-positive flagging, especially with the ‘Blasts/Abn Lympho?’ flag, which leads to a smear rate reduction for such samples. It saves the effort spent on samples that are only old and allows focusing on the pathologic samples needing attention. Sysmex recommends using the Aged Sample Identifier in laboratories experiencing workflow challenges due to a high proportion of aged samples.
Albumin is a small soluble protein that is synthesized in the liver and contained in blood. Albumin is the most abundant protein in blood and serves as an important binding and transport protein. When kidneys are working correctly, they keep important elements such as albumin in the blood. Healthy individuals excrete only low levels of protein through urine on a daily basis. In contrast to this, albuminuria is a pathological condition with larger amounts (>30 mg/24 h) of albumin being present in urine over a longer period. This abnormal condition can be used for an early recognition of nephropathy. The early diagnosis of (micro-)albuminuria can prevent or postpone severe kidney damage.
L'anémieest une anomalie de l'hémogramme caractérisée par une diminution de la concentration en hémoglobine intra-érythrocytaire . Les valeurs déterminant la présence ou l'absence d'anémie dépendent à la fois de l'âge et du sexe. L'hématocrite (Ht) est un paramètre connexe qui est également réduit en cas d'anémie. L'anémie est un symptôme, plutôt qu'une maladie, pouvant avoir pour origine une multitude de causes.
B
Healthy urine usually does not contain bacteria. However, some bacteria can be present if the urine sample was not collected under sterile conditions or if the person is suffering from a urinary tract infection. Bacteria can be differentiated into Gram-positive and Gram-negative bacteria, based on their cell wall composition. Depending on the type of the cell wall, they are susceptible to different antibiotics.
Les basophiles sont les globules blancs les moins représentés dans le sang périphérique et font partie également des granulocytes. Tout comme les éosinophiles, une augmentation de la numération de basophiles est bien souvent le signe, mais pas toujours, d'une allergie ou d'une infection parasitaire. Ils fonctionnent avec les mastocytes comme cellules effectrices dans des processus complexes tels que la chimiotaxie ou l'adhérence cellulaire et ils remplissent un rôle de modulation immunitaire pendant les réactions allergiques.
Bilirubin is generated during the breakdown of haemoglobin which is mainly released during the degradation of old red blood cells in the reticuloendothelial system. It is then bound to albumin and transported through the blood to the liver.
Pathological processes that increase the concentration of conjugated bilirubin in plasma also lead to elevated levels of bilirubin in urine, such as fibrosis and swelling, or necrosis of liver cells.
C
Continuous ambulatory peritoneal dialysis (CAPD) is a dialysis involving the continuous presence of dialysate in the patient’s peritoneal cavity. CAPD fluid is analysed in order to rule out infection, which is the most common problem with peritoneal dialysis.
Urinary casts mainly consist of Tamm-Horsfall mucoprotein (THP). About 50 mg of liquid THP is excreted every day. Therefore, it is normal to find THP in urine.
Hyaline casts (Hy. CAST) are the most common types of casts in urine. They are cylindrical and appear almost transparent. Casts are a result of solidification of THP mucoprotein in the lumen of the kidney tubules. Hyaline casts can be found in urine due to dehydration, fever or vigorous exercise.
Pathological casts (Path. CAST) contain inclusions. They develop when particles – such as red blood cells or tubular epithelial cells – are present during the solidification process of THP. Particles adhere to the fibrillar protein network and get surrounded by it. These casts appear in urine when pathological processes take place in the kidney. Examples: Granular casts, cellular casts, waxy casts.
A new concept optionally embedded in the Extended IPU that becomes active if interferences in the measurement of red blood cells or related parameters (e.g. MCHC) are detected. This refers, for example, to cold agglutination, haemolysis or hypo-osmolarity. The algorithm delivers conclusive information about the cause of interference, suggests the replacement of the affected parameters with their counterparts from the RET analysis and automatically recalculates the RBC indices. In doing so, CBC-O relieves the laboratory by automating the workflow for certain problematic samples.
La Concentration Corpusculaire Moyenne en Hémoglobine est calculée à partir de l'Ht et de l'Hb et reflète la quantité de l'hémoglobine dans les globules rouges par rapport au volume cellulaire. CCMH [g/dL] = Hb/Ht. La plage de référence normale pour la CCMH est constante durant toute la vie, et ne subit que des variations minimes.
La CCMH est également utilisée pour définir des populations normochromes, hypochromes et hyperchromes. Les cellules présentant une trop faible teneur en hémoglobine sont de couleur plus claire et ont une CCMH faible. Une CCMH élevée pour des raisons cliniques est rare et ne se produit virtuellement qu'en cas de sphérocytose ou de déshydratation cellulaire . Les globules rouges hyperchromes présentent une concentration intracellulaire d'Hb, par globule rouge, inhabituellement élevée en raison de la perte volumique de la cellule.
La CCMH est traditionnellement utilisée pour contrôler la performance technique d'un analyseur.
Système logiciel modulaire et évolutif, composé de différents modules intégrés du logiciel (IPU, Extended-IPU, support à distance / Internet) avec une interface utilisateur harmonisée, pour contrôler le flux de travail, les règles de validation, les pâramètres système, la mise en réseau des différents analyseurs.
Concerne la valeur ajoutée des paramètres ou leurs combinaisons, à la fois pour le diagnostic et le traitement/suivi, basée uniquement sur des données probantes.
Creatinine is a breakdown product of creatine phosphate in muscles and depends on a person’s muscle mass. Creatinine is normally produced at a fairly constant rate (approx. 1 g of creatinine is excreted per day). Therefore, the creatinine concentration can be used to interpret results of spontaneously voided urine samples, which show variable dilutions, in a more consistent way.
Crystals can take many different shapes in urine. They are formed if urine solutes – such as inorganic salts or organic compounds – precipitate. Most of the time, crystals are not significant for clinical findings unless the patient has metabolic disorders, calculus formation (also called ‘urolithiasis’), or if medication needs to be regulated. The most important crystals in this context are cystine, tyrosine, leucine and cholesterol.
Méthode utilisée pour mesurer l'hématocrite (Ht) L'Ht est un paramètre, consistant à mesurer le volume total des globules rouges par rapport au volume de sang total, exprimé sous la forme d'un pourcentage ou d'une fraction (unité l/l).
Sur les analyseurs Sysmex, l'Ht est obtenu à l'aide de la technique d'impédance, à partir de la valeur cumulée des hauteurs d'impulsion des différentes cellules. Il est par conséquent mesuré et non calculé, comme c'est le cas pour les autres technologies.
D
Différenciation complète des globules blancs en cinq sous-populations principales qui apparaissent physiologiquement dans certaines concentrations dans le sang périphérique : lymphocytes, monocytes, éosinophiles, basophiles et neutrophiles. La capacité des analyseurs 5 populations à énumérer également les types de cellules les moins abondantes (monocytes, éosinophiles et basophiles) constitue une avancée notoire.
Les résultats sont exprimés en pourcentage de la numération totale des GB et en numérations absolues, celles-ci étant plus riches en informations : en cas de maladie, les rapports sont déformés et par conséquent, les numérations en pourcentage n'ont aucune signification en l'absence de valeurs absolues.
La principale différence avec la technologie différentielle en 3 populations est que l'identification cellulaire repose sur une analyse tridimensionnelle et non sur la seule taille de la cellule, ce qui permet d'identifier les cellules immatures et anormales, et ainsi de cerner la cause potentielle d'une maladie chez un patient.
Les derniers automates d’hématologie sont capables de classer les granulocytes immatures (IG) dans une sixième population et de les exprimer sous forme de numération en pourcentage de la numération totale des GB et en une numération absolue.
Le terme de « différentiel en 6 populations » désigne généralement le différentiel classique en 5 populations et la quantification supplémentaire de granulocytes immatures (IG) constituant la sixième sous-population de globules blancs. En routine, les analyseurs des gammes XN-L et XN Sysmex rapportent la numération IG en tant que paramètre diagnostique : exprimé sous la forme d'une numération en pourcentage de la numération totale des GB et en numération absolue.
Abréviation de « morphologie numérique » (Digital Morphology en anglais), mais également désignation des analyseurs de la gamme DM fabriqués par CellaVision AB.
E
Les éosinophiles entrent dans la catégorie des granulocytes, ils sont remplis de granulations contenant différentes enzymes. Ils peuvent se déplacer et phagocyter (ou ingérer) des particules. Lorsqu'ils tuent des parasites en libérant certaines enzymes cytotoxiques et sont impliqués dans des réactions d'hypersensibilité, l'augmentation de la numération d'éosinophiles est souvent associée à une infection parasitaire ou à une allergie. L'éosinophilie peut également être le signe de maladies malignes, comme c'est le cas dans certains types de néoplasie.
‘Epithelium’ is a general term for cellular tissue that wraps around certain surfaces. Inside the urinary tract, there are different types of epithelial cells: the squamous (Squa. EC) and the non-squamous epithelial cells (Non SEC). The non-squamous cells are further divided into transitional (Tran. EC) and renal tubular epithelial cells (RTEC).
Squamous epithelial cells (Squa. EC) are large, flat, irregularly shaped cells. They contain a small central nucleus and lots of cytoplasm. The cell edge is often folded over and the cell may be rolled up into a cylinder. It is normal to find squamous epithelial cells in urine. They come from the lower end of the urethra or from skin that the urine came into contact with during collection. As such, they may also represent a contamination typical for poorly collected mid-stream urine samples.
Transitional epithelial cells (Tran. EC, urothelial cells) vary in size and shape depending on their origin. They can come from the upper part of the urethra, from the ureters or the renal hilum. It is normal to find low numbers of transitional cells in urine.
Renal tubular epithelial cells (RTEC) are slightly larger than leucocytes and contain a large, round nucleus. They can appear flat, cube-shaped or as a column. They enter the urine from the tubule system of the nephrons. The presence of RTEC in urine indicates kidney problems.
A common, traditional laboratory test serving as a sensitive, yet non-specific marker of inflammation. It can serve to aid diagnosis, and manage and follow-up various autoimmune diseases, acute and chronic infections and tumours. The ESR is also used as a marker of the 'general physical condition' assessed together with the patient's clinical history and physical examination. Automated analysis of the ESR is facilitated with the XN Interrliner module, which can also be integrated into XN-9000/9100 configurations 'Sorting & Archiving' or 'Maximum Workload' including the tube-sorting process.
L'évolutivité du concept XN permet la mise à niveau d'une solution tout en préservant la solution sur mesure. Cela s'applique aussi bien aux valeurs de productivité et aux valeurs cliniques qu'aux services professionnels.
A set of haematological inflammation parameters that quantify and characterise particular lymphocytes (RE-LYMP, AS-LYMP) and the activation status of neutrophils (NEUT-GI, NEUT-RI). These diagnostic parameters provide additional information about the activation of the patients’ immune response and help clinicians monitor inflammatory conditions in more detail. They become available with licence activation on XN systems via XN-DIFF measurement. The use of WPC is of extra value here as it excludes malignancies reliably.
Composant logiciel pour la standardisation et le contrôle du flux de travail et la synchronisation des flux d’échantillons, de commandes et de données (par ex. validation technique avancée reposant sur des règles). Avec la gamme XN, l’
Extended IPU offre une vaste gamme d'applications standard et optionnelles pour les étapes pré-analytiques, analytiques et post-analytiques, ainsi qu’une gestion de la zone de travail qui inclut des outils destinés à standardiser la validation technique et biomédicale et d'autres visant à optimiser le flux de travail.
F
Technologie Sysmex utilisée dans les analyseurs différentiels d'hématologie des gammes X-Class et XN-Class permettant la détection et la différenciation des cellules sanguines des trois lignées majeures après marquage par fluorescence et exposition laser dans une chambre de flux.
Composé chimique qui peut se lier aux autres structures et qui est à l'origine un phénomène de fluorescence. Après excitation avec une lumière d'une certaine longueur d'onde, une lumière d'une longueur d'onde quelque peu supérieure est émise par la molécule. Les électrons au sein de la molécule absorbent la lumière d'excitation (par ex. une lumière laser), sont élevés à un niveau d'énergie supérieur et dans un court laps de temps, retombent à leur niveau initial. À cet instant, ils libèrent la majeure partie du surplus d'énergie sous forme de lumière. Une petite partie de l'énergie est émise sous la forme d'une énergie thermique, par conséquent la longueur d'onde de la lumière émise est plus grande (moindre en énergie) que la longueur d'onde d'excitation. Les longueurs d'ondes excitables et émettrices dépendent des propriétés du fluorochrome.
Les fluorochromes sont utilisés pour marquer par exemple des composants cellulaires spécifiques (par ex. les acides nucléiques), la lumière fluorescente émise pouvant être mesurée. Un photomultiplucateur est utilisé comme détecteur. En d'autres termes, les fluorochromes peuvent servir de marqueurs pour ces composants cellulaires, permettant ainsi une analyse qualitative et quantitative, l'intensité de la lumière fluorescente étant proportionnelle à la quantité de composant spécifique, par ex. l'ARN et / ou l'ADN intracellulaire.
Technologie Sysmex utilisée par nos analyseurs d'hématologie afin d'optimiser le comptage cellulaire. Le flux de gainage permet aux cellules de passer l'une après l'autre l'unité de détection afin d'empêcher les phénomènes de coïncidence ou de recirculation. Les globules rouges sont souvent sujet à ce qu'on appelle "l'effet de forme" lorsqu'ils sont exposés à une accélération rapide dans un fluide en suspension, la focalisation hydrodynamique réduit considérablement le degré d'accélération donc les cellules ne sont pas déformées et gardent leurs propriétés telles que "in vivo".
En utilisant un système de réactifs ingénieux, les analyseurs d’hématologie de la gamme XN Sysmex permettent de différencier les cellules selon leur fonctionnalité, notamment dans les cas où la différenciation est difficile à établir du point de vue de la morphologie. La détection de la fonctionnalité cellulaire est basée sur la composition de la membrane lipidique de chaque cellule et permet de distinguer les cellules matures et immatures ainsi que les cellules réactives et malignes.
Les réactifs uniques des analyseurs XN permettent de tirer des conclusions sur
1. la maturité d'une cellule,
2. la malignité d'une cellule,
3. l’état d'activation d'une cellule.
Différenciation des globules blancs en trois sous-populations (Approche formule).
Sysmex distingue les lymphocytes, les neutrophiles et une population mixte se composant de monocytes, basophiles et éosinophiles. La différenciation en 3 populations permet communément de distinguer les lymphocytes, les monocytes et la population mixte de granulocytes. Il est avantageux de pouvoir déterminer une population neutrophile distincte,car ce sont les tout premiers marqueurs d’une inflammation ou d'un état infectieux, avant les monocytes.
G
Glomerular filtration is the first step in producing urine. The kidneys use this process to filter excess fluid and waste products out of the blood to eliminate them from the body.
The renal corpuscles filter about 1 L blood/min due to a pressure gradient exerted on the capillary walls. The resulting filtrate in the glomerular capsule containing water, glucose, amino acids, uric acid, urea, electrolytes, etc. is known as ‘glomerular filtrate’ or ‘primary urine’.
‘Glomerular filtration rate’ (GFR) is the volume of fluid filtered from the renal glomerular capillaries into the Bowman's capsule per minute. In healthy adults, GFR is about 125 mL/min (i.e. approx. 150 L of primary urine are formed per day) and is an important indicator of kidney function.
The urine of a healthy person only shows trace amounts of sugar, i.e. glucose. Glucose appears in urine when the blood glucose level rises because of an abnormality of the glucose metabolism. The determination of glucose in urine has a high diagnostic value for early detection of disorders such as diabetes mellitus.
Catégorie de globules blancs myéloïdes, caractérisés par la présence de granulatrions dans le cytoplasme. Les granulocytes englobent les neutrophiles, éosinophiles et basophiles. Ils forment le groupe des globules blancs polynucléaires, par opposition aux globules blancs mononucléaires (lymphocytes et monocytes).
La fluorocytométrie en flux permet l'identification des cellules immatures sur la base de leur teneur plus élevée en acide nucléique par rapport à leurs homologues matures. Elle ajoute la numération des granulocytes immatures (IG) en tant que population distincte de la formule leucocytaire. Cette numération IG inclut des promyélocytes, des myélocytes et des métamyélocytes mais pas les neutrophiles non segmentés.
La présence d'IG est toujours pathologique excepté dans la période postpartum immédiate et chez les nourrissons de moins de trois jours.
H
Haemoglobin is the iron-containing red blood pigment in red blood cells that enables the transport of oxygen in the body. The detection of haemoglobin in urine is due to either elevated haemoglobin levels or the presence of red blood cells in the sample. Elevated values of this parameter are an important symptom for injuries, crystals, glomerulonephritis, renal calculi, or urinary tract infections.
A long-term monitoring parameter used to control diabetics' medical status. It has become a frequently ordered test in medical labs nowadays because of the increase in lifestyle diseases such as diabetes. Automated HbA1c testing is facilitated with the Tosoh HLC-723 G11 Analyser, which can also be integrated into XN-9000/9100 configurations 'Sorting & Archiving' or 'Maximum Workload' including the tube-sorting process.
I
Analyse des cellules par cytométrie de flux qui utilise des anticorps de surface ; ce terme est utilisé pour décrire la méthode de référence pour la numération des plaquettes (à l'aide des anticorps CD41/61), avec laquelle l'application PLT-F de Sysmex sur la gamme XN montre une excellente corrélation.
La technique d'impédance repose sur la possibilité d'utiliser un champ électrique, créé entre deux électrodes de charge opposée, pour compter les cellules et déterminer leur taille.
Les cellules sanguines sont de piètres conducteurs d'électricité. Le diluant (réactif) dans lequel elles se trouvent en suspension pendant la numération est une solution isotonique, agissant comme un bon conducteur . En conséquence, lors du passage de chaque cellule par l'orifice situé entre les deux électrodes, la résistance électrique entre celles-ci augmente et cela génère une impulsion électrique proportionnelle à la taille de la cellule.
L'IPR traduit la réponse médullaire érytropoïétique chez les patients anémiques. Cet indice, plus qu'une simple numération RET seule, est utilisé pour évaluer l'adéquation de la réponse médullaire à l'anémie chez les patients. (L'IPR est défini comme suit : IPR = (RET% × Ht) : (0,45 × jours dans le sang). 0,45 représente l'hématocrite idéal dans la formule. A cet hématocrite idéal de 0,45, l'IPR est identique au pourcentage de réticulocytes, lequel est « idéalement » d'environ 1 % chez les individus sains. Chez un patient anémique présentant une bonne réponse médullaire, l'IPR est supérieur à 2,0. Cependant, la conclusion inverse n'est pas nécessairement vraie. Un bon marqueur concernant la réponse médullaire à l'anémie est l'augmentation de la concentration absolue en réticulocytes, ainsi qu'une augmentation marquée de la fraction de réticulocytes immatures (IRF).
Paramètre fournissant une information sur le degré de variation de la taille des globules rouges: l'IDR est une mesure quantitative de la variabilité de la taille des globules rouges, indiquée sous la forme IDR-SD et IDR-CV. Un IDR élevé indique une variation anormale de la taille de chaque globule rouge, appelée anisocytose et observée au microscope.
Le VGM, la TCMH et la CCMH sont couramment désignés comme indices érythrocytaires. Associés à l'IDR, ces indices sont utilisés pour réduire les causes d'anémie chez un patient.
Les solutions de laboratoire Sysmex sont contrôlées intelligemment par un concept de logiciel intégré. Il permet d'harmoniser et de standardiser l'interaction entre l’échantillon physique et le flux des données. Dans un système unique ou dans plusieurs zones de travail, y compris au sein d’un réseau multi-sites.
Toutefois, nous offrons bien plus qu'un logiciel, notamment les services de la Sysmex Academy, des formations numériques et des ateliers éducatifs sur site ainsi que des conseils.
K
Ketones in urine indicate increased fat degradation in the body. This can be caused by an insufficient supply of energy from carbohydrates. During the degradation of fatty acids, intermediary compounds called ‘ketone bodies’ (acetoacetic acid, s-hydroxybutyric acid and acetone) are formed in the liver. Ketones can be detected in urine when increased fat degradation takes place and is particularly important in checking metabolic decompensation in diabetes mellitus.
The kidneys are two bean-shaped organs in the renal system. They perform essential functions, including the regulation of water and electrolyte balance, and the filtration and elimination of metabolic waste products (e.g. urea, uric acid and ammonia), medications and toxic substances. Kidneys also secrete hormones that help produce red blood cells (via the hormone erythropoietin, EPO), regulate blood pressure (via production of renin) and promote bone health (calcium absorption via conversion of calcidiol into calcitriol).
L
Type de laser (également appelé « laser à diodes ») utilisé dans les cytomètres de flux de dernière génération.
Contrairement aux lasers à gaz utilisés précédemment, ces lasers consomment moins d'énergie, sont plus rapidement opérationnels et ont une plus longue durée de vie.
Leucocyte esterase is an enzyme produced in white blood cells – to be more precise, in granulocytes. Detection of leucocyte esterase reveals the presence of granulocytic leucocytes. Elevated values of this parameter are an important symptom for inflammatory diseases of the efferent urinary tract and kidneys.
Les lymphocytes proviennent de la lignée lymphoïde. Les lymphocytes défendent l'organisme contre l'infection en distinguant les propres cellules du corps des cellules étrangères. Les molécules reconnues par l'organisme comme étrangères sont appelées antigènes. Chaque lymphocyte est stimulé par un antigène spécifique. Lorsque les lymphocytes reconnaissent un antigène, ils produisent des substances chimiques afin de lutter contre lui et l'éliminer. Il existe trois principaux types de lymphocytes: les lymphocytes B, les lymphocytes T et les cellules tueuses naturelles (NK). Les lymphocytes appartiennent aux globules blancs mononucléaires. Bien que par rapport à d'autres globules blancs, tous les lymphocytes soient petits et ronds sans granules, il y a une grande variété de sous-types, et les distinguer morphologiquement est délicat.
M
Nom des réactifs de coloration sans méthanol fabriqués par la société RAL Diagnostics, utilisés par les automates de coloration RAL.
La modularité du concept XN permet de créer une solution sur mesure. Cela s'applique aux valeurs cliniques, à la productivité et aux services professionnels.
Les monocytes font partie des cellules mononucléaires, au même titre que les lymphocytes, mais ils proviennent de la lignée myéloïde, dont les cellules sont produites dans la moelle osseuse. Ils peuvent rapidement gagner les foyers infectieux et se différencier en macrophages et cellules dendritiques pour provoquer une réaction immunitaire. Les cellules du système monocyte-macrophage peuvent absorber des particules étrangères et les diviser en antigènes qu'elles peuvent ensuite présenter à leur surface. L'augmentation de la numération de monocytes peut être le signe de différentes maladies, p. ex. une infection ou une inflammation chronique, mais elle peut survenir également dans les cas de maladies malignes telles que la leucémie myélomonocytique chronique.
La MWO intégrée dans l’Extended IPU offre un concept visant à distinguer la monocytose réactive d'une monocytose d'origine possiblement maligne. Le concept de MWO contribue à diminuer le nombre d’examens de frottis sanguins superflus tout en optimisant la détection de la CMML et en améliorant le flux de travail du laboratoire.
Technologie utilisée pour différencier les cellules colorées d'un frottis sanguin ou d’une lame de cytospin par capture d'image et reconnaissance, en utilisant la technologie de réseau neuronal artificiel. Les images à haute résolution de cellules sont représentées sur un écran pour la validation ou autre classification, ce qui permet la transmission des résultats en ligne et la consultation par d'autres experts.
N
A nephron is the microscopic structural and functional filtering unit of the kidney. Each kidney is made up of over one million nephrons that cleanse the blood and balance the constituents of the circulation. A nephron consists of a renal corpuscle, a sophisticated renal tubule system and the associated capillary network.
Nephrons process the blood supplied by afferent arterioles via glomerular filtration, tubular reabsorption and secretion. Many processes take place in different parts of the nephron before the filtrate (primary urine) is modified into the final product referred to as ‘urine’.
Les neutrophiles appartiennent à la catégorie des granulocytes. Ils jouent un rôle important dans la défense immunitaire et sont les premières cellules immunitaires à arriver au foyer d'une infection – généralement en l'espace d'une heure. Ceci se produit au cours d'un processus appelé chimiotaxie. Les neutrophiles peuvent phagocyter d'autres cellules, comme des bactéries, qui semblent néfastes à l'organisme. Pourtant, eux-mêmes ne survivront pas à cette action. Le pus se compose essentiellement de neutrophiles lysés et de bactéries digérées. La numération absolue et relative des neutrophiles peut donner des informations pour le diagnostic et le suivi des infections et est également prise en compte pendant la chimiothérapie. Une numération accrue de neutrophiles peut également se retrouver physiologiquement dans des situations non pathologiques, p. ex. après un stress ou chez les fumeurs.
Nitrite is the result of nitrate reduction. Various bacteria that cause urinary tract infections (UTI) produce enzymes that turn nitrate into nitrite. The presence of nitrite in urine is an indirect confirmation of bacterial infection (bacteriuria). Common microorganisms that can cause urinary tract infections, such as Escherichia coli, Enterobacter, Citrobacter, Klebsiella, and Proteus species, produce enzymes that reduce urinary nitrate to nitrite.
A negative NIT test strip result does not exclude a urinary tract infection because there could be bacteria present which do not produce nitrite. Therefore, nitrite is specific but not sensitive for UTI. Furthermore, with strong bacterial growth, nitrite may eventually be degraded to nitrogen, which means that remaining nitrite levels in the sample may be below the limit of detection.
Principe de numération des cellules sanguines utilisé dans les analyseurs Sysmex : le nombre de cellules sanguines est déterminé à partir du nombre d'impulsions générées dans un volume de sang fixe. Cette approche présente l'avantage de ne pas nécessiter de calibration par l'utilisateur.
Paramètre de recherche indiquant la présence de cellules à haute fluorescence, qui représentent des cellules activées (lymphocytes B sécrétant des anticorps /plasmocytes) si les pathologies hématologiques systémiques peuvent être exclues.
Analyse hématologique classique reposant sur 8 paramètres comprenant la numération des GR, GB et PLT ainsi que la détermination des valeurs Hb, HCT, VGM, TCHM, CCMH.Analyse hématologique classique reposant sur 8 paramètres comprenant les numérations de GR, GB et PLT + détermination des valeurs Hg, HCT, VGM, TCHM, CCMH.
Les analyseurs reposant sur ce principe de numération établissent le décompte des cellules sanguines à partir du nombre d'impulsions générées au cours d'une période donnée. De tels systèmes sont sujets à erreurs en raison de l'obstruction de l'orifice de comptage. En d'autres termes, il est nécessaire de les re-calibrer régulièrement.
P
Paramètres fournissant des informations pertinentes d'un point de vue diagnostique, en plus des paramètres principaux ou en rapport avec ceux-ci, destinés à une utilisation interne au laboratoire.
Paramètres fournissant des informations pertinentes d'un point de vue diagnostique, en plus des paramètres diagnostiques ou en rapport avec ceux-ci, destinés à une utilisation interne au laboratoire en vue de valider des résultats et faire un bilan diagnostique. Les résultats de ces paramètres ne sont pas destinés à être transmis directement, par ex. aux services hospitaliers ou aux cliniciens. En revanche, les résultats diagnostiques de ces derniers en rapport avec les paramètres diagnostiques peuvent l'être.
Paramètres fournissant des informations pertinentes d'un point de vue diagnostique au cas par cas, censées être transmises aux cliniciens.
Paramètres avancés sur certains analyseurs d'hématologie Sysmex : IG, RET-He, IPF, NRBC, paramètres avancés d'inflammation, cellules souches XN ; ils offrent une valeur ajoutée par rapport à l'analyse d'hématologie classique et une base permettant de générer une valeur clinique.
Les pathologies des globules blancs peuvent affecter soit la lignée myéloïde, soit la lignée lymphoïde. Elles peuvent être le résultat de maladies réactives et non réactives (néoplasiques ou malignes). Des évolutions réactives sont observées au cours de maladies infectieuses ou inflammatoires, tandis que des altérations malignes sont le signe de leucémies, de lymphomes et d'autres tumeurs malignes hématologiques. Pour distinguer les différentes maladies liées aux globules blancs, il est essentiel de déterminer à la fois leur nombre, leur nature exacte et leur stade de maturité. L'analyse hématologique automatisée est une composante cruciale du processus de diagnostic et aide à identifier la présence d'une maladie en fournissant une numération précise des cellules et en soulignant les populations de cellules en trop grand nombre.
The pH describes how acidic or alkaline a substance is based on the hydrogen ion concentration. If urine is persistently acidic or alkaline, this can indicate a disturbed acid-base balance. Persistently alkaline pH values point towards urinary tract infection. For microscopy, it is good to bear in mind that at pH levels above 7, cells can lyse faster than under normal (slightly acidic to nearly neutral) conditions.
Paramètres plaquettaires, par analogie à l'hématocrite, mais calculés à partir du VPM et de la numération PLT (PCT = VPM x PLT).
Application concernant les valeurs cliniques, disponible en option sur les analyseurs de la gamme XN-Series, et destinée à mesurer les plaquettes, grâce au marquage par fluorescence spécifique (avec un degré de précision et de fidélité élevé également dans la plage thrombocytopénique). Il a été démontré une très bonne corrélation avec la méthode de référence (CD41 / 61).
Grâce au canal PLT-F , vous pouvez obtenir la fraction de plaquettes immatures (IPF) qui reflète l'activité médullaire thrombocytopoïétique, en faisant ainsi un outil particulièrement utile pour détecter les thrombocytopénies et leurs causes éventuelles.
Composés utilisés comme fluorochromes utilisé en association avec un laser à diodes comme source lumineuse dans les dispositifs d'hématologie Sysmex.
Ces composés présentent plusieurs avantages : leur absorption maximale peut être modulée afin de répondre à la longueur d'onde laser exacte, la perméabilité des cellules et du noyau peuvent être adaptées et l'affinité aux composants cellulaires spécifiques, tels que des acides nucléiques, peut être générée selon les besoins ‒ par des changements de la structure moléculaire.
Dans les analyseurs X-Class et XN-Series, plusieurs agents différents contenant de la polyméthine sont utilisés pour des analyses de différenciation spécifiques des cellules matures et immatures de l'ensemble des trois lignées cellulaires.
Primary urine is the fraction of blood plasma, which is filtered out by renal corpuscles. Due to the massive blood supply to the kidneys and the large number of glomerular filtration units, the body produces about 150 litres of primary urine daily. Approximately 99% of primary urine is reabsorbed through the tubule epithelium so that only 1.8 litres have to be excreted every day. The components of primary urine correspond to the composition of protein-free blood plasma.
Procédé de mesure Sysmex (sans cyanure), permettant la détection d'Hb, fournissant des résultats particulièrement fiables grâce à la lyse efficace des GR, des GB et des lipides, entraînant une réduction significative des interférences potentielles.
Optimisation et harmonisation des processus de laboratoire intégrés, axées sur le coût total de la propriété et leur contribution dans l’obtention de résultats rapides et de grande qualité.
Most proteins are normally contained in blood because they are too large to fit through the glomerular membrane. However, if these filters are damaged, proteinuria – the presence of protein in urine – can occur. Protein in urine is a frequent symptom of renal diseases, but it is not very specific. Protein levels in urine can be temporarily increased due to exercise, fever or stress.
R
Red blood cells deliver oxygen to the body’s tissues by travelling through the circulatory system. They are round, smooth and have a red tinge. If red blood cells appear in this intact shape, they are called isomorphic or eumorphic and do not come from the glomerulus. If red blood cells become damaged, they are called dysmorphic red blood cells. Their deformation occurs when they pass through the glomerular structures of the kidney, but it can also happen when they are exposed to urine for a prolonged time. The term for pathological dysmorphic red blood cells is ‘acanthocytes’. Their presence can indicate a glomerular disease such as glomerulonephritis.
If there are a few red blood cells in urine, this can be considered normal. A high number of red blood cells, however, can indicate the presence of injuries, crystals, renal calculi or urinary tract infections.
The renal corpuscle is the site of the filtration of blood plasma. It consists of the glomerulus, and the glomerular capsule, or ‘Bowman's capsule’. Afferent arterioles form a network of high-pressure capillaries called the ‘glomerulus’. The tuft of glomerular capillaries filters the blood based on particle size and the filtrate is captured by the surrounding cup-shaped chamber, the Bowman’s (glomerular) capsule.
The renal tubule is a long and convoluted structure that emerges from the glomerulus and is divided into three main parts based on function: the proximal convoluted tubule, the loop of Henle (with descending and ascending limbs) and the distal convoluted tubule. After passing through the renal tubule, the filtrate continues to the collecting duct system.
Liée à l'imprécision : mesures en série répétées dans les mêmes conditions.
Liée à l'imprécision : mesures en série répétées dans des conditions modifiées : autre jour, autre opérateur, autres lots, autre laboratoire.
Valeur dérivée à partir du scattergramme des RET en vue de déterminer la valeur RET-He, qui reflète l'hémoglobinisation de la population de réticulocytes.
Application concernant les valeurs cliniques, disponible en option sur les analyseurs de la gamme XN, destinée à quantifier et différencier les réticulocytes en fonction de leurs stades de maturité (HFR, MFR, LFR), grâce à un marquage de fluorescence spécifique. Une numération optique des plaquettes (PLT-O) peut également être fournie.
RET définit également la fraction de réticulocytes immatures (IRF=HFR+MFR) et l'équivalent de la concentration en hémoglobine dans les réticulocytes (RET-He), évaluant ainsi et la quantité (activité érythropoïétique) et la qualité (synthèse et intégration de l'hémoglobine) des GR nouvellement formés. Ce paramètre est important dans les diagnostics différentiels de l'anémie. Le RET-He est également un indicateur précoce en cas de changements dans l'hémoglobinisation des GR, ce qui est utile par ex. dans le suivi thérapeutique.
S
Les scattergrammes (diagramme de dispersion) sont générés en représentant pour chaque cellule comptée deux signaux différents. En d'autres termes il s'agit d'une analyse bi-dimensionnelle. Les signaux peuvent être obtenus à partir d'une impédance volumétrique, d'une énergie électromagnétique à haute fréquence, des techniques optiques (une lumière à diffusion latérale et frontale) et de marquage cytochimique (fluorescence à diffusion latérale).
Il est possible d'évaluer et d'afficher plus d'une population cellulaire simultanément. Ces deux populations distinctes de cellules sont différenciées l'une de l'autre grâce au système ACAS au critère de discrimination fixe.
Il est possible d'enregistrer plus de deux signaux différents par cellule, permettant ainsi d'en déduire plus d'un scattergramme pour distinguer et afficher les différentes populations cellulaires.
Concept Sysmex qui contribue à faire de l'environnement professionnel un lieu plus convivial, qui donne la priorité aux utilisateurs. Dans notre concept SILENT DESIGN®, nous nous concentrons sur cinq principes fondamentaux pour faciliter la prise en main par l'utilisateur : utilisateur - espace - surface - gamme - longévité. Nos produits SILENT DESIGN® tiennent compte de ces cinq piliers pour une expérience unique.
Urinary specific gravity is based on the concentration of solutes in urine. It measures the ratio of urine density compared to water and provides information on the kidney’s ability to concentrate urine. If the specific gravity values drop below 1.010 g/mL urine, cells undergo faster lysis than in normal conditions (1.010 to 1.030 g/mL).
Logiciel permettant de contrôler les performances de nos analyseurs XN : il s'agit d'une application protégeant l'environnement fonctionnel ainsi que d'autres applications supervisant les besoins de maintenance et le contrôle des performances techniques.
Articles spécifiques dédiés au contexte clinique et diagnostique dans une optique scientifique et informative.
Méthode Sysmex permettant d'évaluer les signaux cellulaires individuels durant la mesure et de déterminer la morphologie de la population à laquelle ces cellules appartiennent. Cette méthode permettant une plus grande flexibilité, la variation biologique entre les patients est prise en compte. Elle induit des résultats plus précis en termes de différenciation, notamment avec des échantillons pathologiques, où l'apparence morphologique des cellules est probablement altérée par la maladie.
T
La teneur corpusculaire moyenne en hémoglobine est déterminée à partir des GR et de l'Hb. TCMH [pg] = Hb/GR. La plage de référence normale pour la TCMH dépend de l'âge. La valeur TCMH tend à être proportionnelle au VGM, la taille d'une cellule est largement conditionnée par sa teneur en hémoglobine.
Les cellules ayant une TCMH normale sont appelées normochromes et celles avec des valeurs basses ou élevées sont respectivement désignées par les termes hypochromes et hyperchromes. Une TCMH basse indique une teneur trop faible des cellules en hémoglobine due à une production inadaptée. Les cellules sont dites hypochromes quand leur apparence est pâle lors de l'examen au microscope.
Mesure d'un échantillon reposant sur des règles avec un profil d'analyse différent ou avancé en vue d'obtenir des résultats plus fiables.
Mesure d'un échantillon reposant sur des règles avec un profil d'analyse identique à la commande initiale en vue d'obtenir des résultats fiables.
TWO streamlines the entire platelet analysis workflow in the laboratory as it optimises the triggering of PLT-F reflex tests and supports the differential diagnosis of thrombocytopenic patients and their monitoring.
The new TWO algorithm is embedded in the Extended IPU and can be used in conjunction with the PLT-F application.
U
Interface logicielle des analyseurs Sysmex.
The ureter is a tube that carries urine from the kidney to the urinary bladder. There are two ureters, one attached to each kidney.
The urethra arises from the base of the bladder and transports urine to the outside of the body for disposal. The urethra is the only urinary structure that differs significantly between females and males, due to the dual role of the male urethra in transporting both urine and semen.
The urinary bladder (also called ‘urocyst’ or ‘vesica’) is a hollow muscular organ that collects and stores urine from the kidneys via the ureters before disposal by urination. It is a highly distensible (or elastic) organ. A typical adult human bladder will hold between 300 and 500 mL before the urge to empty occurs, but it can hold considerably more.
Urobilinogen is a colourless by-product of bilirubin reduction. It is excreted in increased amounts in urine when the functional capacity of the liver is impaired or overloaded, or when the liver is bypassed. However, a value of zero is also critical since this may indicate biliary obstruction.
V
Le volume globulaire moyen est calculé à partir des GR et de l'Ht, VGM[fL] = Ht/GR. La plage de référence normale pour le VGM dépend de l'âge. Les termes « normocytaire », « microcytaire » et « macrocytaire » sont utilisés pour décrire respectivement les populations de globules avec un VGM normal, faible et élevé.
La taille d'un globule rouge dépendant de sa teneur en hémoglobine, un trouble de la production de cette dernière se traduira par des érythrocytes plus petits que la normale, microcytose. Les globules macrocytaires apparaissent en cas d'altération de la division des cellules précurseurs des érythrocytes dans la moelle osseuse.
W
White blood cells, also called leucocytes, are vital parts of the immune system. They help protect the body against infections and foreign invaders. WBC are round and, if they are granulocytes, granulated. They measure approximately 1.5 to 2 times the diameter of a red blood cell. In urine, the most common type of WBC are neutrophils (i.e. neutrophilic granulocytes), whereas lymphocytes or eosinophils (eosinophilic granulocytes) are rare findings in urine. A small number of WBC can be present in healthy urine but increased counts can point towards inflammation or infection within the urinary system.
Application concernant les valeurs cliniques, disponible en option sur les analyseurs bleus (XN-20) de la gamme XN. Destinée à mesurer les précurseurs leucocytaires, en fournissant en conséquence un système d'alarmes à deux niveaux (en association avec l'application standard XN-DIFF) pour les anomalies leucocytaires lymphoïdes et myéloïdes, elle contribue ainsi à éliminer les alertes faussement positives et les différenciations manuelles, et permet de se concentrer sur les échantillons présentant des troubles de type néoplasique.
X
Groupe d'analyseurs d'hématologie se composant des modèles XS-serie, reposant tous sur la technologie de la fluorocytométrie en flux et fournissant un différentiel sanguin en 5 populations ainsi qu'une analyse variable des paramètres étendus ouvrant d'autres options diagnostiques.
A new measurement option utilising the WPC measurement channel for the quantification of haematopoietic progenitor cells (HPC). The XN Stem Cells method has been shown to be comparable with the CD34 immune flow cytometry count in mobilised peripheral blood.
Application concernant les valeurs cliniques, disponible en option sur les analyseurs de la gamme XN, pour une mesure automatisée et standardisée des différents liquides biologiques. Cette fonction permet une analyse rapide sans prétraitement des échantillons, disponible à toute heure du jour, avec une excellente reproductibilité des résultats et une réduction du nombre de numérations manuelles.
Outre la quantification des GB et GR, cette fonction fournit une numération totale des cellules et les GB sont différenciés en cellules mononucléaires et polymorphonucléaires, fournissant des indications rapides sur des états infectieux et autres anomalies.
Application concernant les valeurs cliniques, disponible sur les analyseurs de la gamme XN, pour l'analyse NFS complète.
La valeur ajoutée par rapport à la NFS standard réside dans la numération des érythroblastes (NRBC), sous la forme d'une population distincte, ce qui peut s'avérer important dans l'identification de développements critiques pour des patients en soins intensifs. Cela signifie également que les valeurs de la numération GB ne sont pas touchées par la présence de NRBC. Cette fonction élimine la nécessité d'une numération manuelle des NRBC, accélère le temps de traitement et fait progresser la standardisation.
Application concernant les valeurs cliniques, disponible sur les analyseurs de la gamme XN, pour une analyse différentielle des GB dans les échantillons sanguins. La valeur ajoutée par rapport à une formule en 5 populations classique réside dans la numération des granulocytes immatures (IG), sous la forme d'une population distincte et dont l'analyse tri-dimensionnelle est d'une grande sensibilité.
Un mode « LOW WDF » spécial, déclenché automatiquement au besoin, permet de différencier également, avec une meilleure fiabilité, les échantillons leucopéniques, grâce à un volume de numération augmenté.
Y
Yeast cells are smooth, colourless and usually egg-shaped. They have birefringent walls, come in different sizes and often show budding. The most common type of yeast found in urine is Candida albicans. Yeast cells in urine can come from either skin-related or vaginal contaminations or can indicate mycotic urinary tract infections.